... five1.1
Originally six documents were planned with Volume I on the ISO Mission and II on the ISO Satellite but both have now been merged in Volume I in Version 2.0.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... entry1.2
http://adswww.harvard.edu/
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... response2.1
Relative spectral detector response means detector response normalised to its maximum value.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... bandpass2.2
The factor of $2 \sqrt{3}$ is a normalising factor forcing the filter width to be equal to that of a rectangular filter with height $\rm R_{mean}$.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... Y-direction3.1
In the PV phase the opposite scheme was implemented, with the source in the -Y axis beam; this was corrected from revolution 70 onwards
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... diameter3.2
For the $20''{\times}32''$ aperture the 32$''$ value had to be used.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... 3363.3
PGA v5.3, AOT-Logic v3.4.0
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... reduction4.1
The CRE amplifier gain in the AC coupled version as shown in Figure 2.5 is limited by the ratio $G=C_C / C_F =56$. Consequently, the reference voltage for the detector bias, $U_{in}$ at the CRE input, varied as $\Delta U_{in} = \Delta U_{out} / G$. For a maximum integrator voltage amplitude of $\Delta U_{out} =2 V$, the variation of the CRE input voltage $\Delta U_{in} \approx 40 mV$
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... PHT-C5.1
for C100 chopped observations only the centre pixel of the array is used for the point source flux determination. The $f_{PSF}$ refers to the psf correction of that pixel, see also Section 10.12.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... describing5.2
$C1$ is the same parameter as the $C1$ factor given on page 58 of the `ISOPHOT Observers Manual' 1994, [21]. Note that the values of $C1$ have changed.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... observation6.1
These times correspond to the Start_TDT and End_TDT times in the Pointed Observation File (POF)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... uncertainty7.1
the uncertainty given here is different from OLP where the factor 2 in the denominator has been omitted
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
... ftp.iso.vilspa.esa.es11.1
Archive products can also be downloaded directly from the `Latest Results' screen by clicking on the `Retrieve' button after IDA Version 5.2, released in July 2002
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.